  • Description:
    Variable Angle LCP &Two-Column Volar Distal Radius Plate 2.4 featuring variable angle locking technology is a versatile plate for the treatment of intra- and extra-articular fractures and osteotomies of the distal radius.Variable Angle LCP&Two-Column Volar Distal Radius Plate …(steel)Was this helpful?Peo ...
  • Get Price carbonsteels@yeah.net

(grade) Variable Angle LCP&Two-Column Volar Distal Radius Plate 2 Variable angle double column radius volar locking plate

Two-Column Volar Distal Radius Plate 2.4. Variable Angle LCP &Two-Column Volar Distal Radius Plate 2.4 featuring variable angle locking technology is a versatile plate for the treatment of intra- and extra-articular fractures and osteotomies of the distal radius. Contact Us. Instructions for Use. Surgical Technique.(grade) What is a bendable 2 column?What is a bendable 2 column?Bendable Two columns allow independent ne contouring of the radial and intermedi- ate columns The Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4, featuring variable angle locking technology, is indi- cated for intra- and extra-articular fractures and osteotomies of the distal radius.Variable Angle LCP Two-Column Volar Distal Radius Plate 2 Variable angle double column radius volar locking plate

What is distal radius and distal ulna?What is distal radius and distal ulna?The distal radius and distal ulna form a three-column biome- chanical construction 3 The ulnar column is the distal ulna, the triangular brocar- tilage and the distal radio-ulnar joint. The intermediate column is the medial part of the distal radius, with the lunate fossa and the sigmoid notch.Variable Angle LCP Two-Column Volar Distal Radius Plate 2 Variable angle double column radius volar locking plate(grade) What is variable angle LCP?What is variable angle LCP?Variable Angle LCP Two-Column Volar Distal Radius Plates 2.4 are indicated for the xation of intra- and extra-articular fractures and osteotomies of the distal radius. 6DePuy SynthesVariable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical TechniqueVariable Angle LCP Two-Column Volar Distal Radius Plate 2 Variable angle double column radius volar locking plate(grade)2.4 mm VA Dorsal Distal Radius Plate J&J Medical Devices

The 2.4 mm Variable Angle LCP &Dorsal Distal Radius Plate is part of the 2.4 mm Variable Angle LCP Distal Radius System. The low-profile dorsal distal radius plates are intended for the double plate technique, and are available in 6 different styles of plates.

2.4 mm Variable Angle LCP Dorsal Distal Radius Plate TG

2 Synthes 2.4 mm Variable Angle LCP Dorsal Distal Radius Plate Technique Guide 2.4 mm Variable Angle LCP Dorsal Distal Radius Plate. For fragment-specific fixation with variable angle (VA) locking technology. The low-profile dorsal distal radius plates are intended for the double-plate technique. All implants are available in(grade)2.4 mm Variable Angle LCP Volar Rim Distal Radius (steel)The 2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates are intended for fixation of complex intra- and extra- articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures intra-articular fractures exiting the epiphysis intra-articular fractures exiting the (grade)2.4 mm variable angle lcp DiSTal raDiuS SySTem(steel)2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius Plate choice of 3-hole or 5-hole shaft available left or right, with 4-hole or 5-hole head conguration lcp combi holes allow xed-angle locking screw xation with angular stability in the threaded

2.4mm Variable Angle Distal Radius Volar Plate J&J Variable angle double column radius volar locking plate

The 2.4 mm Variable Angle LCP &Volar Rim Distal Radius Plate is part of the 2.4 mm Variable Angle LCP Distal Radius System. The plates are anatomically contoured and allow buttressing of distal fragments, and are designed to address complex intra-articular and extra-articular distal radius (grade)2.4mm Variable Angle LCP&Distal Radius Plate J&J Variable angle double column radius volar locking plate(steel)The 2.4 mm Variable Angle LCP &Two-Column Volar Distal Radius Plate is part of the 2.4 mm Variable Angle LCP Distal Radius System. The plates are anatomically contoured to match the anatomy of the distal radius, and are designed to address both simple and complex fractures. Contact Us. Instructions for Use.(grade)Biomechanical Analysis of a Volar Variable-Angle Locking Variable angle double column radius volar locking plate(steel) Watch this video to learn more as Dr. Fischer and Dr. Richard cover the VA LCP Two-Column VVolar Distal Radius Plate, Extra-Long product overview. Variable angle double column radius volar locking plate 2.4 mm Variable Angle Locking Intercarpal Variable angle double column radius volar locking plate

Distal radius fracturesDesign of locking mechanism in Variable angle double column radius volar locking plate

May 01, 2016In general, there are two categories of volar locking plates for distal radius fracture, according to the mechanism between the screw and plate fixation system. The monoaxial locking plate (MLP) is a fixed-angle locking screw with the plate, and the polyaxial locking plate (PLP) is a variable-angle locking screw with the plate.(grade)Distal radius fracturesDesign of locking mechanism in Variable angle double column radius volar locking plate(steel)May 01, 2016In general, there are two categories of volar locking plates for distal radius fracture, according to the mechanism between the screw and plate fixation system. The monoaxial locking plate (MLP) is a fixed-angle locking screw with the plate, and the polyaxial locking plate (PLP) is a variable-angle locking screw with the plate.(grade)Evaluating the necessity of bone augmentation for distal Variable angle double column radius volar locking plate(steel)Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4mm&steel plate used during the operation are the same regardless of the number of combi-holes; thus, even plates of different lengths can be compared with each other (Fig. 3). Similarly, we made corrections for the radial height statistics. R was defined as the distance from the distal

Evaluation of a polyaxial angle-stable volar plate in a Variable angle double column radius volar locking plate

One radius of each pair received a juxta-articular 2.4-mm locking compression plate (LCP) Volar Distal Radius Plate, whilst the contralateral one received a 2.4-mm Variable Angle Locking Compression Plate (LCP) Two-Column Volar Distal Radius Plate (both plates Synthes, Oberdorf, Switzerland).(grade)File Size 2MBPage Count 442.4 MM VArIABLE ANgLE LCP DISTAL rADIuS SySTEM(steel)2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius Plate Choice of 3-hole or 5-hole shaft Available left or right, with 4-hole or 5-hole head con guration LCP Combi holes allow xed-angle locking screw xation with angular stability in the threaded(grade)Geminus Volar Distal Radius Plate - Skeletal Dynamics Variable angle double column radius volar locking plate(steel)Geminus Volar Distal Radius Plate . Two heads are better than one. Variable angle double column radius volar locking plate Hook Plate accessory extends plate fixation capability to secure volar marginal fragments. Options Are Good. Variable angle double column radius volar locking plate FreeFix&slots accommodate compression and locking screws at any position within any slot.

Images of Variable Angle Double Column Radius Volar Lockin

imagesVariAx 2 Distal Radius Stryker(steel)Variable angle locking plate system for treating volar and dorsal distal fractures. Plating that fits. The VariAx 2 Distal Radius Plating System provides you with a comprehensive range of anatomic plating options that work with a common instrument and screw platform.(grade)Leveraging the Plate Reliably Restoring Volar Tilt of Variable angle double column radius volar locking plate(steel)sized volar locking plate is selected and positioned in the desired proximal-distal and medial-lateral dimensions. The authors most commonly use a 3-hole, 2.4-mm, variable-angle distal radius locking compres-sion plate (Synthes Inc, West Chester, Pennsylvania). A threaded drill guide inserted into one of the distal locking(grade)Mechanical Failure of the Distal Radius Volar Locking (steel)Key words bone plates; radius fractures introduction Volar locking plate is an increasingly popular choice for distal radial fractures, owing to its wider availability and reliability of the locking technology adapted to the wrist.1 Variable angle locking screws facilitate column

Mechanical Testing of Two Different Variable Angle Locking Variable angle double column radius volar locking plate

Background In recent years, the volar locking plating of distal radius fractures has become popular. Locking mechanisms have improved with the variable angle locking mechanism. The aim of the study was to evaluate the different behavior of different screw plate locking mechanisms and, furthermore, the influence on the stability in the fracture setting.(grade)VariAx 2 Distal Radius Stryker(steel)Variable angle locking plate system for treating volar and dorsal distal fractures. Plating that fits. The VariAx 2 Distal Radius Plating System provides you with a comprehensive range of anatomic plating options that work with a common instrument and screw platform.(grade)Variable Angle LCP Two-Column Volar Distal Radius (steel)Two columns allow independent ne contouring of the radial and intermedi- ate columns The Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4, featuring variable angle locking technology, is indi- cated for intra- and extra-articular fractures and osteotomies of

Variable Angle LCP&Two-Column Volar Distal Radius Plate

Variable Angle LCP &Two-Column Volar Distal Radius Plate 2.4/2.7 mm, Extra-Long featuring variable angle locking technology is a versatile plate for the treatment of intra- and extra-articular fractures and osteotomies of the distal radius, with or without extension into the radial diaphysis.(grade)Variable Angle Locking Hand System Synthes Vo Llnwd(steel)Double Medical Distal Radius Locking Plate, variable angle Double Medical Distal Radius Locking Plate, variable angle by Double Medical Technology Inc. 6 months ago 2 minutes, 9 seconds 477 views LCP-VA Elbow System LCP-VA Elbow System by Nectone 8 years ago 5 minutes, 59 seconds 8,320 views New product from Synthes for treating fractures Variable angle double column radius volar locking plate(grade)Variable Angle Volar Plates, Variable Angle Volar Plates Variable angle double column radius volar locking plate(steel)Variable Angle Volar Two Column Distal Radius Safety Lock Plate 2.4 (6 Head Holes)

Variable Angle LCP &Two-Column Volar Distal Radius Plate 2.4 featuring variable angle locking technology is a versatile plate for the treatment of intra- and extra-articular fractures and osteotomies of the distal radius.Variable Angle LCP&Two-Column Volar Distal Radius Plate

Was this helpful?People also askWhat is variable angle locking plate?What is variable angle locking plate?Variable angle locking plate system for treating volar and dorsal distal fractures. The VariAx 2 Distal Radius Plating System provides you with a comprehensive range of anatomic plating options that work with a common instrument and screw platform. Plates utilize SmartLock technology which permits polyaxial screw placement.VariAx 2 Distal Radius Stryker(grade)Variable-angle locking plate with or without double-tiered Variable angle double column radius volar locking plate(steel)Background Double-tiered subchondral support (DSS) procedure is two-row fixation in which proximal screws support the dorsal subchondral bone, whereas distal screws support the volar central subchondral bone, using the volar variable-angle locking plate to achieve better anatomical reduction. We examined whether DSS improves clinical outcome, complication (grade)Variable-angle locking plate with or without double-tiered Variable angle double column radius volar locking plate(steel)Background Double-tiered subchondral support (DSS) procedure is two-row fixation in which proximal screws support the dorsal subchondral bone, whereas distal screws support the volar central subchondral bone, using the volar variable-angle locking plate to achieve better anatomical reduction. We examined whether DSS improves clinical outcome, complication

Volar Distal Radius Plate Rim Plate J&J Medical Devices

Eight anatomically contoured volar extra-articular distal radius plates; Variable angle LCP &(VA LCP ®) System holes in the head of the plate combined with variable angle locking screws allow up to 15° off-axis angulation in all directions; Four columns of threads in the variable angle locking hole provide four points of threaded locking between the variable angle LCP &Plate

Technical Parameters

Inspection & Control

we have a comprehensive set of inspection and control tools for quality control, materials analysis, mechanical properties,ultrasonic testing, magnetic particle inspection, etc..

universal tester

universal tester

Impact test

Impact test

X-ray test

X-ray test

Universal Testing Machine

MTS 300kN Electromechanical Universal Testing Machine

Three-coordinate bevel gear precision inspection report

Our Services

To ensure better cooperation,our factory provides the following services to the buyers:

1. OEM&ODM:As the special samples and drawings.

2. The small order is acceptable.

3. Professional services

4. Comprehensive and professional after-sale services

We are a supplier of bulletproof steel material & machinery products. We have extensive experience in the manufacture of bulletproof steel plate, other Bulletproof peripheral products. Welcome to sending drawings and inquiry.

Production Workflow

OEM

According to the drawings or samples, customize steel products you need.

More

ODM

According to the specific requirements, design steel products for you, and generate the production.

More